An Electrochemical Sensor for Prothrombin-Time Test
XIN Lifei,LIU Hong *
School of Biological Science and Medical Engineering, Southeast University, 210096
*Correspondence author
#Submitted by
Subject:
Funding: none
Opened online:29 March 2018
Accepted by: none
Citation: XIN Lifei,LIU Hong.An Electrochemical Sensor for Prothrombin-Time Test[OL]. [29 March 2018] http://en.paper.edu.cn/en_releasepaper/content/4744019
 
 
As a new interdisciplinary, blood coagulation and thrombosis, being involved in the development and progression of many diseases, have a prominent clinical significance. Prothrombin time (PT time) is the time when calcium and tissue factor is added into the blood sample until when the blood sample completely clots. Clinically, PT time is an extremely sensitive screening index in coagulation system, it has an irreplaceable influence to patients\' daily medication and related treatments as it can primarily reflect the normality of the extrinsic coagulation. Until recently, most automated coagulation analyzers used in hospitals can detect a variety of samples and projects at the same time with high accuracy. However it could only be operated by the professionals, not to mention the high production and testing costs. For these reasons, the frequency and ease-of-operation of the detection have been limited. In order to develop a real-time and household detection method, paper-chips and POCT technology are mainly utilized in this work. Paper-chips possesses their own advantages, as it can easily reflect the blood clotting process by detecting a change in the conductance of blood during the blood coagulation process. After a series of design, tests and improvements, a chip for PT time testing is fabricated. Using this chip, the PT time of several blood samples are tested, and the testing results confirmed that the further improved chip can complete the measurement and correction of blood PT time test. Compared with conventional coagulation analyzer, paper-chips have several intrinsic advantages such as reduced cost, higher accuracy, and better application in POCT use. We believe that pushing the further experimental products to market could fill the vacancy in the domestic industry.
Keywords:analytical chemistry; electrochemistry; prothrombin time; point-of-care test
 
 
 

For this paper

  • PDF (0B)
  • ● Revision 0   
  • ● Print this paper
  • ● Recommend this paper to a friend
  • ● Add to my favorite list

    Saved Papers

    Please enter a name for this paper to be shown in your personalized Saved Papers list

Tags

Add yours

Related Papers

Statistics

PDF Downloaded 59
Bookmarked 0
Recommend 0
Comments Array
Submit your papers