Home > Papers

 
 
Gas sensors for CO2 detection based on RGO-PEI films at room temperature
ZHOU Yong 1,JIANG Yadong 2,XIE Guangzhong 2 * #,WU Mei 2,TAI Huiling 2
1.School of Optoelectronic Information, State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China (UESTC), ChengDu 610054
2.School of Optoelectronic Information, State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China (UESTC), Chengdu, 610054
*Correspondence author
#Submitted by
Subject:
Funding: the National Natural Science Foundation of China(No.Grant Nos. 61176006, 61006036), Specialized Research Fund for the Doctoral Program of Higher Education (No.20120185110012)
Opened online:18 September 2013
Accepted by: none
Citation: ZHOU Yong,JIANG Yadong,XIE Guangzhong.Gas sensors for CO2 detection based on RGO-PEI films at room temperature[OL]. [18 September 2013] http://en.paper.edu.cn/en_releasepaper/content/4558623
 
 
In this paper, Polyethyleneimine (PEI) and Reduced Graphene Oxide (RGO) were selected as sensing materials for carbon dioxide detection. Two kinds of sensors with different sensitive film structures, i.e., RGO-PEI composite film and RGO-PEI bi-layer film were fabricated by airbrushing the sensitive films on interdigitated electrodes (IDEs). Response performances of both sensors at room temperature were investigated. Results showed that sensors with bi-layer film exhibited smaller baseline drift and more stable sensing characteristics than the counterparts with composite film. Furthermore, bi-layer film sensors with different quantity of PEI solution deposited were studied. Performances of long-time stability, repeatability, low concentration of detection for carbon dioxide, and measurements of response time and recovery time were investigated. It was found that appropriate weight ratio of RGO and PEI was critical for sensing response. In addition, the sensor with bi-layer film exhibited a better repeatability but had longer response time and recovery time than RGO single-layer sensor, and both of them could detect as low as 20 ppm carbon dioxide gas. The relevant sensing mechanisms were studied as well.
Keywords:Gas sensor; RGO; PEI; Carbon dioxide; Room temperature
 
 
 

For this paper

  • PDF (0B)
  • ● Revision 0   
  • ● Print this paper
  • ● Recommend this paper to a friend
  • ● Add to my favorite list

    Saved Papers

    Please enter a name for this paper to be shown in your personalized Saved Papers list

Tags

Add yours

Related Papers

Statistics

PDF Downloaded 717
Bookmarked 0
Recommend 5
Comments Array
Submit your papers