Authentication email has already been sent, please check your email box: and activate it as soon as possible.
You can login to My Profile and manage your email alerts.
If you haven’t received the email, please:
|
|
There are 1 papers published in subject: > since this site started. |
Results per page: |
Select Subject |
Select/Unselect all | For Selected Papers |
Saved Papers
Please enter a name for this paper to be shown in your personalized Saved Papers list
|
1. Extension of The Implicit Curve-Fitting Method for Fast Calculation of Thermodynamic Properties to Subcooled Refrigerant | |||
Guoliang Ding,Zhigang Wu,Weizhe Han,Kaijian Wang,Masaharu Fukaya | |||
Dynamic and Electronic Engineering 04 March 2008 | |||
Show/Hide Abstract | Cite this paper︱Full-text: PDF (0 B) | |||
Abstract:Calculations of refrigerant thermal properties are desired to be very fast and stable in cases of simulation of refrigeration system, etc. The implicit regress and explicit calculation method is a quite good method for the fast and stable calculation of refrigerant thermodynamic properties, and it has been used for saturated, two-phase and superheated refrigerants. In this paper, the implicit regress and explicit calculation method is extended to the calculation of subcooled refrigerants. As an example, the fast calculation formulae for subcooled refrigerant R22, R134a, R410A and R407C are developed based on the source data derived from NIST REFPROP 7.1. The comparison shows that, for pure refrigerant, the total mean relative deviations of the fast calculation formulae are less than 0.02 % and the maximum relative deviations are less than 0.60%; for refrigerant mixtures, the total mean relative deviations of the fast calculation formulae are less than 0.08%. The maximum relative deviation of R410A is less than 3.36% while the maximum relative deviation of R407C is less than 0.87%. The mean calculation speed of the fast calculation formulae for thermal properties of pure refrigerant and that of refrigerant mixtures are near 100 times and more than 1500 times faster than those of NIST REFPROP 7.1, respectively. | |||
TO cite this article:Guoliang Ding,Zhigang Wu,Weizhe Han, et al. Extension of The Implicit Curve-Fitting Method for Fast Calculation of Thermodynamic Properties to Subcooled Refrigerant[OL].[ 4 March 2008] http://en.paper.edu.cn/en_releasepaper/content/18990 |
Select/Unselect all | For Selected Papers |
Saved Papers
Please enter a name for this paper to be shown in your personalized Saved Papers list
|
|
Results per page: |
About Sciencepaper Online | Privacy Policy | Terms & Conditions | Contact Us
© 2003-2012 Sciencepaper Online. unless otherwise stated